Lennox Furnace Code 33 usually means the pressure switch circuit is open or not proving airflow when the inducer motor should be running. The single most likely fix is clearing a blocked pressure-switch hose or venting restriction, then confirming the inducer and switch tubing are dry, tight, and undamaged.
On a Lennox Furnace, Error Code 33 typically points to a pressure switch problem during the ignition sequence. The control board expects the inducer motor to create negative pressure in the heat exchanger and venting system, which closes the pressure switch. If that signal does not reach the PCB, the furnace stops the heating cycle to prevent unsafe combustion or flue gas spillage.
Technically, this fault can be caused by an open pressure switch, a blocked intake or exhaust pipe, condensate trapped in the pressure tubing, a weak inducer motor, or damaged wiring between the switch and control board. In high-efficiency condensing furnaces, water in the collector box, drain trap, or vent can also interfere with pressure readings. The fault is often electrical and airflow-related at the same time, so both sides need to be checked.
Because the pressure switch is a safety device, do not bypass it to make the furnace run. A furnace that cannot prove proper draft may have a venting restriction, inducer failure, or control issue that can lead to repeated shutdowns or unsafe operation. The goal is to find out why the switch is not proving, not just to clear the code.
Leaves, insect nests, snow, ice, or debris in the vent termination can reduce inducer draft enough to keep the pressure switch open. Even a partial restriction can trigger Code 33, especially during cold or wet weather.
The small rubber or silicone hose between the inducer housing and pressure switch must hold vacuum properly. If it is split, disconnected, brittle, or filled with condensate, the pressure switch cannot sense draft correctly.
If the inducer wheel is dirty, the motor bearings are worn, or the capacitor is weak on designs that use one, draft may be too low to close the switch. You may hear humming, slow startup, or an abnormal rattling noise before the error appears.
A pressure switch can fail mechanically or electrically after years of cycling. Corroded terminals, a loose spade connector, damaged wiring harness, or poor continuity back to the control board can also create the same fault code.
On condensing Lennox furnaces, a clogged drain trap or collector box can alter pressure in the combustion path. Water backing up into the inducer housing or tubing often causes intermittent pressure-switch faults that appear and disappear.
Follow the steps below one at a time — many error codes can be fixed faster than they look.
Tools you may need: screwdriver, multimeter, flashlight
Safety warning: Disconnect power before opening any panels or touching internal components.
Yes, you can try a basic reset by shutting off power to the furnace for 15 to 30 minutes and restarting it. If the code comes back, the reset did not fix the underlying problem, and you should check the venting, pressure switch hose, condensate drain, and inducer operation.
It is a safety-related fault, so you should take it seriously. Code 33 means the furnace is not proving proper draft through the pressure switch circuit, which can be caused by blocked venting or combustion-air problems. The furnace usually locks out to prevent unsafe burner operation.
No. The pressure switch is a critical safety device that confirms the inducer is moving combustion gases correctly. Bypassing it can allow the furnace to run with a blocked vent, poor draft, or flue gas hazard, and it can also damage components or create a much more expensive repair.
The cost depends on the cause. A simple vent cleaning, hose replacement, or condensate drain service is usually on the lower end, while inducer motor or control board work is more expensive. Labor rates vary widely, but diagnosis is often straightforward if the technician can reproduce the fault.
Cold or wet conditions can expose marginal venting and condensate problems. Snow, ice, heavy wind, or extra moisture can block vent terminations, fill pressure tubing with water, or slow drainage in condensing furnaces. That changes the pressure signal enough for the control board to post Code 33.
Call a professional if the inducer does not start, the pressure switch does not change state during testing, the furnace repeatedly locks out, or you find signs of burnt wiring, water in electrical compartments, or damaged venting. Combustion diagnostics and pressure readings should be verified with proper instruments.